Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Urol Case Rep ; 54: 102728, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38601085

RESUMO

Retrocaval ureter is a rare congenital anomaly with few reported cases worldwide. In this case report, we describe a clinical presentation that demonstrates the stereotypical imaging features of a retrocaval ureter on ultrasound, computed tomography and nuclear imaging studies in a 38-year-old male patient who fits the classic reported patient demographics.

2.
Abdom Radiol (NY) ; 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38523146

RESUMO

PURPOSE: Accurate staging of ovarian cancer is critical to guide optimal management pathways. North American guidelines recommend contrast-enhanced CT as the primary work-up for staging ovarian cancer. This meta-analysis aims to compare the diagnostic accuracy of contrast-enhanced CT alone to PET/CT for detecting abdominal metastases in patients with a new or suspected diagnosis of ovarian cancer. MATERIALS AND METHODS: A systematic review of MEDLINE, EMBASE, Scopus, the Cochrane Library, and the gray literature from inception to October 2022 was performed. Studies with a minimum of 5 patients evaluating the diagnostic accuracy of contrast-enhanced CT and/or PET/CT for detecting stage 3 ovarian cancer as defined by a surgical/histopathological reference standard ± clinical follow-up were included. Study, clinical, imaging, and accuracy data for eligible studies were independently acquired by two reviewers. Primary meta-analysis was performed in studies reporting accuracy on a per-patient basis using a bivariate mixed-effects regression model. Risk of bias was evaluated using QUADAS-2. RESULTS: From 3701 citations, 15 studies (918 patients with mean age ranging from 51 to 65 years) were included in the systematic review. Twelve studies evaluated contrast-enhanced CT (6 using a per-patient assessment and 6 using a per-region assessment) and 11 studies evaluated PET/CT (7 using a per-patient assessment and 4 using a per-region assessment). All but one reporting study used consensus reading. Respective sensitivity and specificity values on a per-patient basis were 82% (67-91%, 95% CI) and 72% (59-82%) for contrast-enhanced CT and 87% (75-94%) and 90% (82-95%) for PET/CT. There was no significant difference in sensitivities between modalities (p = 0.29), but PET/CT was significantly more specific than CT (p < 0.01). Presumed variability could not be assessed in any single category due to limited studies using per-patient assessment. Studies were almost entirely low risk for bias and applicability concerns using QUADAS-2. CONCLUSION: Contrast-enhanced CT demonstrates non-inferior sensitivity compared to PET/CT, although PET/CT may still serve as an alternative and/or supplement to CT alone prior to and/or in lieu of diagnostic laparoscopy in patients with ovarian cancer. Future revisions to existing guidelines should consider these results to further refine the individualized pretherapeutic diagnostic pathway.

3.
BMJ Case Rep ; 17(3)2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38453225

RESUMO

In this case report, we describe an uncommon presentation of Cushing's syndrome in a patient in their 60s who presented to the emergency department with left-sided chest pain. The initial workup for the patient was unremarkable except for an elevated blood pressure and elevated fasting plasma glucose. A CT scan of the chest, abdomen and pelvis was performed, demonstrating a splenic artery thrombus with multiple splenic infarcts, in addition to a combination of macronodular adrenal hyperplasia, bilateral gynecomastia, centripetal fat distribution and suspected mild bone demineralisation. Adrenocorticotropic hormone-independent macronodular adrenal hyperplasia, a rare aetiology responsible for Cushing's syndrome, was raised as a potential unifying diagnosis for the patient's hypercoagulable status, which was subsequently confirmed on an endocrinological investigation. The case report underscores the importance of communicating clinically relevant details to the imaging specialist in combination with considering a broad differential, including endocrine disorders, when evaluating an undifferentiated patient with atypical imaging findings.


Assuntos
Hiperplasia Suprarrenal Congênita , Síndrome de Cushing , Humanos , Masculino , Glândulas Suprarrenais/patologia , Hiperplasia Suprarrenal Congênita/complicações , Hormônio Adrenocorticotrópico , Síndrome de Cushing/diagnóstico por imagem , Síndrome de Cushing/etiologia , Hidrocortisona , Hiperplasia/patologia , Tomografia Computadorizada por Raios X , Pessoa de Meia-Idade , Idoso
4.
5.
J Am Coll Radiol ; 21(1): 107-117, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37634790

RESUMO

BACKGROUND: Preferred size-threshold recommendations for management of incidental adrenal lesions remain controversial. PURPOSE: This meta-analysis aimed to compare the diagnostic accuracy of different size thresholds for detecting malignancy in patients with incidental adrenal lesions on imaging. MATERIALS AND METHODS: A systematic review of MEDLINE, Embase, Scopus, the Cochrane Library, and the gray literature, covering the period from inception to September 2021, was performed. Studies with >10 patients evaluating the diagnostic accuracy of imaging size thresholds for detecting malignancy in patients with incidental adrenal lesions and no prior history of cancer were included. Study, clinical, imaging, and accuracy data for eligible studies were independently acquired by two reviewers. Primary meta-analysis was performed using a bivariate mixed-effects regression model. Risk of bias was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. RESULTS: From 2,690 citations, 40 studies (9,794 patients with mean age ranging from 41 to 66 years) were included. Most (36 of 40) were retrospective single-center studies. CT with or without MRI served as the index test(s). Sensitivity and specificity values, respectively, by size threshold used in the included studies were as follows: 85% (95% confidence interval [CI] 74%-91%) and 39% (95% CI 23%-57%) for 3-cm thresholds; 85% (95% CI 78%-90%) and 75% (95% CI 62%-85%) for 4-cm thresholds; 70% (95% CI 56%-81%) and 74% (95% CI 59%-85%) for 5-cm thresholds; and 75% (95% CI 67%-82%) and 77% (95% CI 62%-87%) for 6-cm thresholds. No cause for variability in sensitivity or specificity was identified on subgroup analysis of the 4-cm threshold. Nearly half of the studies (19 of 40) had at least one QUADAS-2 domain with a high risk of bias. CONCLUSIONS: A 4-cm size threshold demonstrates the highest combined sensitivity and specificity, with a preserved specificity compared with higher size thresholds, but with a trend toward improved sensitivity. Future research reevaluating 4-5 cm size thresholds while excluding characteristically benign lesions by imaging may help redefine a size threshold that has improved specificity but preserved sensitivity, compared with the existing 4-cm threshold.


Assuntos
Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Sensibilidade e Especificidade , Imageamento por Ressonância Magnética
6.
World J Radiol ; 15(10): 293-303, 2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-37969136

RESUMO

BACKGROUND: Hepatic steatosis is a very common problem worldwide. AIM: To assess the performance of two- and six-point Dixon magnetic resonance (MR) techniques in the detection, quantification and grading of hepatic steatosis. METHODS: A single-center retrospective study was performed in 62 patients with suspected parenchymal liver disease. MR sequences included two-point Dixon, six-point Dixon, MR spectroscopy (MRS) and MR elastography. Fat fraction (FF) estimates on the Dixon techniques were compared to the MRS-proton density FF (PDFF). Statistical tests used included Pearson's correlation and receiver operating characteristic. RESULTS: FF estimates on the Dixon techniques showed excellent correlation (≥ 0.95) with MRS-PDFF, and excellent accuracy [area under the receiver operating characteristic (AUROC) ≥ 0.95] in: (1) Detecting steatosis; and (2) Grading severe steatosis, (P < 0.001). In iron overload, two-point Dixon was not evaluable due to confounding T2* effects. FF estimates on six-point Dixon vs MRS-PDFF showed a moderate correlation (0.82) in iron overload vs an excellent correlation (0.97) without iron overload, (P < 0.03). The accuracy of six-point Dixon in grading mild steatosis improved (AUROC: 0.59 to 0.99) when iron overload cases were excluded. The excellent correlation (> 0.9) between the Dixon techniques vs MRS-PDFF did not change in the presence of liver fibrosis (P < 0.01). CONCLUSION: Dixon techniques performed satisfactorily for the evaluation of hepatic steatosis but with exceptions.

7.
Urol Case Rep ; 50: 102505, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37521279

RESUMO

Congenital renal anomalies are common imaging findings and can often be detected antenatally. In some cases, these anomalies may go undetected and present in adulthood. We report a very rare case of unilateral renal agenesis in a 22-year-old male associated with an ipsilateral dilated blind-ended ureter that ectopically inserted into the seminal vesicle. This unique combination of developmental anomalies can lead to a variety of clinical presentations and requires careful monitoring and management.

8.
Eur Radiol ; 33(12): 8605-8616, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37439933

RESUMO

OBJECTIVES: This systematic review and meta-analysis evaluated the diagnostic accuracy of CT and MRI for differentiating atypical lipomatous tumors and malignant liposarcomas from benign lipomatous lesions. METHODS: MEDLINE, EMBASE, Scopus, the Cochrane Library, and the gray literature from inception to January 2022 were systematically evaluated. Original studies with > 5 patients evaluating the accuracy of CT and/or MRI for detecting liposarcomas with a histopathological reference standard were included. Meta-analysis was performed using a bivariate mixed-effects regression model. Risk of bias was evaluated using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2). This study is registered on PROSPERO, number CRD42022306479. RESULTS: Twenty-six studies with a total of 2613 patients were included. Mean/median reported patient ages ranged between 50 and 63 years. The summary sensitivity and specificity of radiologist gestalt for detecting liposarcomas was 85% (79-90% 95% CI) and 63% (52-72%), respectively. Deep depth to fascia, thickened septations, enhancing components, and lesion size (≥ 10 cm) all demonstrated sensitivities ≥ 85%. Other imaging characteristics including heterogenous/amorphous signal intensity, irregular tumor margin, and nodules present demonstrated lower sensitivities ranging from 43 to 65%. Inter-reader reliability for radiologist gestalt within studies ranged from fair to substantial (k = 0.23-0.7). Risk of bias was predominantly mixed for patient selection, low for index test and reference standard, and unclear for flow and timing. CONCLUSION: Higher sensitivities for detecting liposarcomas were achieved with radiologist gestalt, deep depth to fascia, thickened septations, enhancing components, and large size. Combined clinical and imaging scoring and/or radiomics both show promise for optimal performance, though require further analysis with prospective study designs. CLINICAL RELEVANCE: This pooled analysis evaluates the accuracy of CT and MRI for detecting atypical lipomatous tumors and malignant liposarcomas. Radiologist gestalt, deep depth to fascia, thickened septations, enhancing components, and large size demonstrate the highest overall sensitivities. KEY POINTS: • The summary sensitivity and specificity of radiologist gestalt for detecting liposarcomas was 85% (79-90% 95% CI) and 63% (52-72%), respectively. • Radiologist gestalt, deep depth to fascia, thickened septations, enhancing components, and large tumor size (≥ 10 cm) showed the highest sensitivities for detecting atypical lipomatous tumors/well-differentiated liposarcomas and malignant liposarcomas. • A combined clinical and imaging scoring system and/or radiomics is likely to provide the best overall diagnostic accuracy, although currently proposed scoring systems and radiomic feature analysis require further study with prospective study designs.


Assuntos
Lipoma , Lipossarcoma , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Prospectivos , Imageamento por Ressonância Magnética , Lipossarcoma/diagnóstico por imagem , Lipossarcoma/patologia , Lipoma/diagnóstico por imagem , Lipoma/patologia , Tomografia Computadorizada por Raios X , Sensibilidade e Especificidade
9.
Abdom Radiol (NY) ; 48(6): 2060-2073, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37041393

RESUMO

Chronic liver disease (CLD) is a common source of morbidity and mortality worldwide. Non-alcoholic fatty liver disease (NAFLD) serves as a major cause of CLD with a rising annual prevalence. Additionally, iron overload can be both a cause and effect of CLD with a negative synergistic effect when combined with NAFLD. The development of state-of-the-art multiparametric MR solutions has led to a change in the diagnostic paradigm in CLD, shifting from traditional liver biopsy to innovative non-invasive methods for providing accurate and reliable detection and quantification of the disease burden. Novel imaging biomarkers such as MRI-PDFF for fat, R2 and R2* for iron, and liver stiffness for fibrosis provide important information for diagnosis, surveillance, risk stratification, and treatment. In this article, we provide a concise overview of the MR concepts and techniques involved in the detection and quantification of liver fat, iron, and fibrosis including their relative strengths and limitations and discuss a practical abbreviated MR protocol for clinical use that integrates these three MR biomarkers into a single simplified MR assessment. Multiparametric MR techniques provide accurate and reliable non-invasive detection and quantification of liver fat, iron, and fibrosis. These techniques can be combined in a single abbreviated MR "Triple Screen" assessment to offer a more complete metabolic imaging profile of CLD.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Ferro , Fígado/diagnóstico por imagem , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Biomarcadores , Fibrose , Técnicas de Imagem por Elasticidade/métodos
10.
Skeletal Radiol ; 52(6): 1089-1100, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36385583

RESUMO

BACKGROUND: Differentiating atypical lipomatous tumors (ALTs) and well-differentiated liposarcomas (WDLs) from benign lipomatous lesions is important for guiding clinical management, though conventional visual analysis of these lesions is challenging due to overlap of imaging features. Radiomics-based approaches may serve as a promising alternative and/or supplementary diagnostic approach to conventional imaging. PURPOSE: The purpose of this study is to review the practice of radiomics-based imaging and systematically evaluate the literature available for studies evaluating radiomics applied to differentiating ALTs/WDLs from benign lipomas. REVIEW: A background review of the radiomic workflow is provided, outlining the steps of image acquisition, segmentation, feature extraction, and model development. Subsequently, a systematic review of MEDLINE, EMBASE, Scopus, the Cochrane Library, and the grey literature was performed from inception to June 2022 to identify size studies using radiomics for differentiating ALTs/WDLs from benign lipomas. Radiomic models were shown to outperform conventional analysis in all but one model with a sensitivity ranging from 68 to 100% and a specificity ranging from 84 to 100%. However, current approaches rely on user input and no studies used a fully automated method for segmentation, contributing to interobserver variability and decreasing time efficiency. CONCLUSION: Radiomic models may show improved performance for differentiating ALTs/WDLs from benign lipomas compared to conventional analysis. However, considerable variability between radiomic approaches exists and future studies evaluating a standardized radiomic model with a multi-institutional study design and preferably fully automated segmentation software are needed before clinical application can be more broadly considered.


Assuntos
Lipoma , Lipossarcoma , Humanos , Lipossarcoma/patologia , Lipoma/diagnóstico por imagem
11.
World J Radiol ; 14(9): 319-328, 2022 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-36186517

RESUMO

BACKGROUND: The 2018 ovarian-adnexal reporting and data system (O-RADS) guidelines are aimed at providing a system for consistent reports and risk stratification for ovarian lesions found on ultrasound. It provides key characteristics and findings for lesions, a lexicon of descriptors to communicate findings, and risk characterization and associated follow-up recommendation guidelines. However, the O-RADS guidelines have not been validated in North American institutions or amongst less experienced readers. AIM: To evaluate the diagnostic accuracy and inter-reader reliability of ultrasound O-RADS risk stratification amongst less experienced readers in a North American institution with and without pre-test training. METHODS: A single-center retrospective study was performed using 100 ovarian/adnexal lesions of varying O-RADS scores. Of these cases, 50 were allotted to a training cohort and 50 to a testing cohort via a non-randomized group selection process in order to approximately equal distribution of O-RADS categories both within and between groups. Reference standard O-RADS scores were established through consensus of three fellowship-trained body imaging radiologists. Three PGY-4 residents were independently evaluated for diagnostic accuracy and inter-reader reliability with and without pre-test O-RADS training. Sensitivity, specificity, positive predictive value, negative predictive value (NPV), and area under the curve (AUC) were used to measure accuracy. Fleiss kappa and weighted quadratic (pairwise) kappa values were used to measure inter-reader reliability. Statistical significance was P < 0.05. RESULTS: Mean patient age was 40 ± 16 years with lesions ranging from 1.2 to 22.5 cm. Readers demonstrated excellent specificities (85%-100% pre-training and 91%-100% post-training) and NPVs (89%-100% pre-training and 91-100% post-training) across the O-RADS categories. Sensitivities were variable (55%-100% pre-training and 64%-100% post-training) with malignant O-RADS 4 and 5 Lesions pre-training and post-training AUC values of 0.87-0.95 and 0.94-098, respectively (P < 0.001). Nineteen of 22 (86%) misclassified cases in pre-training were related to mischaracterization of dermoid features or wall/septation morphology. Fifteen of 17 (88%) of post-training misclassified cases were related to one of these two errors. Fleiss kappa inter-reader reliability was 'good' and pairwise inter-reader reliability was 'very good' with pre-training and post-training assessment (k = 0.76 and 0.77; and k = 0.77-0.87 and 0.85-0.89, respectively). CONCLUSION: Less experienced readers in North America achieved excellent specificities and AUC values with very good pairwise inter-reader reliability. They may be subject to misclassification of potentially malignant lesions, and specific training around dermoid features and smooth vs irregular inner wall/septation morphology may improve sensitivity.

12.
SA J Radiol ; 26(1): 2386, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35747784

RESUMO

Background: Hepatocellular carcinoma (HCC) can be diagnosed non-invasively, provided certain imaging criteria are met. However, the recent Liver Imaging Reporting and Data System (LI-RADS) version 2018 has not been widely validated. Objectives: This study aimed to evaluate the diagnostic accuracy and reader reliability of the LI-RADS version 2018 lexicon amongst fellowship trained radiologists compared with an expert consensus reference standard. Method: This retrospective study was conducted between 2018 and 2020. A total of 50 contrast enhanced liver magnetic resonance imaging (MRI) studies evaluating focal liver observations in patients with cirrhosis, hepatitis B virus (HBV) or prior HCC were acquired. The standard of reference was a consensus review by three fellowship-trained radiologists. Diagnostic accuracy including sensitivity, specificity, positive predictive value (PPV), negative predictive values (NPV) and area under the curve (AUC) values were calculated per LI-RADS category for each reader. Kappa statistics were used to measure reader agreement. Results: Readers demonstrated excellent specificities (88% - 100%) and NPVs (85% - 100%) across all LI-RADS categories. Sensitivities were variable, ranging from 67% to 83% for LI-RADS 1, 29% to 43% for LI-RADS 2, 100% for LI-RADS 3, 70% to 80% for LI-RADS 4 and 80% to 84% for LI-RADS 5. Readers showed excellent accuracy for differentiating benign and malignant liver lesions with AUC values > 0.90. Overall inter-reader agreement was 'good' (kappa = 0.76, p < 0.001). Pairwise inter-reader agreement was 'very good' (kappa ≥ 0.90, p < 0.001). Conclusion: The LI-RADS version 2018 demonstrates excellent specificity, NPV and AUC values for risk stratification of liver observations by radiologists. Liver Imaging Reporting and Data System can reliably differentiate benign from malignant lesions when used in conjunction with corresponding LI-RADS management recommendations.

13.
Intractable Rare Dis Res ; 11(2): 46-51, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35702579

RESUMO

99mTc-sestamibi SPECT/CT is a promising nuclear medicine imaging investigation for benign renal lesions such as renal oncocytomas. The purpose of this article is to i) review the current literature on 99mTc-sestamibi SPECT/CT, ii) to review to current application of 99mTc-sestamibi SPECT/CT for indeterminate renal lesion imaging, and iii) to discuss present limitations and areas for future research. The literature has been reviewed up to April 2022 for articles relating to the application of 99mTc-sestamibi SPECT/CT for benign renal lesions including a recently published systematic review and meta-analysis performed by the authors. One study evaluating 99mTc-sestamibi SPECT alone and five studies evaluating 99mTc-sestamibi SPECT/CT have been performed to date. 99mTc-sestamibi SPECT/CT demonstrates high sensitivity and specificity for detecting benign renal lesions, particularly renal oncocytomas. 99mTc-sestamibi SPECT/CT demonstrates near-perfect specificity for benign and low-grade renal lesions. The optimal quantified threshold ratio for tumor-to-background renal parenchyma radiotracer uptake for a positive result is > 0.6. In this article, we propose a modified diagnostic algorithm for small enhancing renal masses measuring 1-4 cm in which suspected benign lesions after conventional imaging are considered for 99mTc-sestamibi SPECT-CT. In this algorithm, positive studies can be monitored with active surveillance rather than requiring invasive biopsy and/or targeted therapy.

14.
World J Radiol ; 14(1): 19-29, 2022 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-35126875

RESUMO

BACKGROUND: The American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) was introduced to standardize the ultrasound characterization of thyroid nodules. Studies have shown that ACR-TIRADS reduces unnecessary biopsies and improves consistency of imaging recommendations. Despite its widespread adoption, there are few studies to date assessing the inter-reader agreement amongst radiology trainees with limited ultrasound experience. We hypothesize that in PGY-4 radiology residents with no prior exposure to ACR TI-RADS, a statistically significant improvement in inter-reader reliability can be achieved with a one hour training session. AIM: To evaluate the inter-reader agreement of radiology residents in using ACR TI-RADS before and after training. METHODS: A single center retrospective cohort study evaluating 50 thyroid nodules in 40 patients of varying TI-RADS levels was performed. Reference standard TI-RADS scores were established through a consensus panel of three fellowship-trained staff radiologists with between 1 and 14 years of clinical experience each. Three PGY-4 radiology residents (trainees) were selected as blinded readers for this study. Each trainee had between 4 to 5 mo of designated ultrasound training. No trainee had received specialized TI-RADS training prior to this study. Each of the readers independently reviewed the 50 testing cases and assigned a TI-RADS score to each case before and after TI-RADS training performed 6 wk apart. Fleiss kappa was used to measure the pooled inter-reader agreement. The relative diagnostic performance of readers, pre- and post-training, when compared against the reference standard. RESULTS: There were 33 females and 7 males with a mean age of 56.6 ± 13.6 years. The mean nodule size was 19 ± 14 mm (range from 5 to 63 mm). A statistically significant superior inter-reader agreement was found on the post-training assessment compared to the pre-training assessment for the following variables: 1. "Shape" (k of 0.09 [slight] pre-training vs 0.67 [substantial] post-training, P < 0.001), 2. "Echogenic foci" (k of 0.28 [fair] pre-training vs 0.45 [moderate] post-training, P = 0.004), 3. 'TI-RADS level' (k of 0.14 [slight] pre-training vs 0.36 [fair] post-training, P < 0.001) and 4. 'Recommendations' (k of 0.36 [fair] pre-training vs 0.50 [moderate] post-training, P = 0.02). No significant differences between the pre- and post-training assessments were found for the variables 'composition', 'echogenicity' and 'margins'. There was a general trend towards improved pooled sensitivity with TI-RADS levels 1 to 4 for the post-training assessment while the pooled specificity was relatively high (76.6%-96.8%) for all TI-RADS level. CONCLUSION: Statistically significant improvement in inter-reader agreement in the assigning TI-RADS level and recommendations after training is observed. Our study supports the use of dedicated ACR TI-RADS training in radiology residents.

16.
Abdom Radiol (NY) ; 46(10): 4967-4973, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34185128

RESUMO

PURPOSE: The objective of this study is to evaluate the diagnostic accuracy, interobserver variability, and common lexicon pitfalls of the ACR O-RADS scoring system among staff radiologists without prior experience to O-RADS. MATERIALS AND METHODS: After independent review of the ACR O-RADS publications and 30 training cases, three fellowship-trained, board-certified staff radiologists scored 50 pelvic ultrasound exams using the O-RADS system. The diagnostic accuracy and area under receiver operating characteristic were analyzed for each reader. Overall agreement and pair-wise agreement between readers were also analyzed. RESULTS: Excellent specificities (92 to 100%), NPVs (92 to 100%), and variable sensitivities (72 to 100%), PPVs (66 to 100%) were observed. Considering O-RADS 4 and O-RADS 5 as predictors of malignancy, individual reader AUC values range from 0.94 to 0.98 (p < 0.001). Overall inter-reader agreement for all 3 readers was "very good," k = 0.82 (0.73 to 0.90, 95% CI, p < 0.001). Pair-wise agreement between readers were also "very good," k = 0.86-0.92. 14 out of 150 lesions were misclassified, with the most common error being down-scoring of a solid lesion with irregular outer contours. CONCLUSION: Even without specific training, experienced ultrasound readers can achieve excellent diagnostic performance and high inter-reader reliability with self-directed review of guidelines and cases. The study highlights the effectiveness of ACR O-RADS as a stratification tool for radiologists and supports its continued use in practice.


Assuntos
Radiologistas , Humanos , América do Norte , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Ultrassonografia
17.
AJR Am J Roentgenol ; 217(1): 31-39, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33909462

RESUMO

OBJECTIVE. This systematic review and meta-analysis evaluates the diagnostic accuracy of MRI for differentiating malignant (MPNSTs) from benign peripheral nerve sheath tumors (BPNSTs). MATERIALS AND METHODS. A systematic review of MEDLINE, Embase, Scopus, the Cochrane Library, and the gray literature from inception to December 2019 was performed. Original articles that involved at least 10 patients and that evaluated the accuracy of MRI for detecting MPNSTs were included. Two reviewers independently extracted clinical and radiologic data from included articles to calculate sensitivity, specificity, PPV, NPV, and accuracy. A meta-analysis was performed using a bivariate mixed-effects regression model. Risk of bias was evaluated using QUADAS-2. RESULTS. Fifteen studies involving 798 lesions (252 MPNSTs and 546 BPNSTs) were included in the analysis. Pooled and weighted sensitivity, specificity, and AUC values for MRI in detecting MPNSTs were 68% (95% CI, 52-80%), 93% (95% CI, 85-97%), and 0.89 (95% CI, 0.86-0.92) when using feature combination and 88% (95% CI, 74-95%), 94% (95% CI, 89-96%), and 0.97 (95% CI, 0.95-0.98) using diffusion restriction with or without feature combination. Subgroup analysis, such as patients with neurofibromatosis type 1 (NF1) versus those without NF1, could not be performed because of insufficient data. Risk of bias was predominantly high or unclear for patient selection, mixed for index test, low for reference standard, and unclear for flow and timing. CONCLUSION. Combining features such as diffusion restriction optimizes the diagnostic accuracy of MRI for detecting MPNSTs. However, limitations in the literature, including variability and risk of bias, necessitate additional methodologically rigorous studies to allow subgroup analysis and further evaluate the combination of clinical and MRI features for MPNST diagnosis.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias de Bainha Neural/diagnóstico por imagem , Neoplasias de Bainha Neural/patologia , Diagnóstico Diferencial , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Abdom Radiol (NY) ; 46(3): 1249-1255, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32926211

RESUMO

PURPOSE: This scoping review evaluated the currently available data related to abdominal imaging in the SARS-CoV-2 infection. METHOD: A systematic review of MEDLINE, EMBASE, SCOPUS, and Web of Science was performed from inception to July 15, 2020 using PRISMA-ScR guidelines. The review included case reports and series discussing radiologic manifestations of SARS-CoV-2 infection in abdominal imaging studies. Studies published from inception to March 31, 2020, were independently screened and reviewed by one author, and another author reviewed studies published after March 31 to July 15, 2020. Study screening and full-text review for publications before March 31, 2020, was performed by one author, and another author for publications after March 31 to July 15, 2020. RESULTS: Thirty-six studies were included in qualitative synthesis. The prevalence of gastrointestinal symptoms is roughly 18% and includes loss of appetite, nausea, vomiting, diarrhea, and abdominal pain. Sixteen percent of COVID-19 cases may only present with gastrointestinal symptoms. Many patients presenting this way demonstrate evidence of COVID-19 incidentally through abdominal CT imaging at the lung bases. Studies published to date have also reported abdominal imaging findings including small and large bowel wall thickening, fluid-filled colon, pneumatosis intestinalis, pneumoperitoneum, intussusception, and ascites. CONCLUSION: Gastrointestinal manifestations and imaging manifestations of SARS-CoV-2 infection are increasingly reported and warrant specific attention during abdominal imaging.


Assuntos
COVID-19/complicações , Diagnóstico por Imagem/métodos , Gastroenteropatias/complicações , Gastroenteropatias/diagnóstico por imagem , Abdome/diagnóstico por imagem , Humanos , SARS-CoV-2
19.
Eur J Gastroenterol Hepatol ; 32(2): 237-245, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32282542

RESUMO

INTRODUCTION: The purpose of this systematic review and meta-analysis was to evaluate the diagnostic accuracy of liver and spleen stiffness on magnetic resonance elastography (MRE) for detecting clinically significant portal hypertension. METHODS: A systematic review of MEDLINE, EMBASE, Scopus, the Cochrane Library, and the Grey Literature through to 15 August 2019 was performed. Original articles with >10 patients evaluating liver and/or spleen stiffness on MRE using a reference standard of portal hypertension defined as intractable ascites, esophageal varices, encephalopathy and/or death were included in analysis. Patient, clinical, MRI, and diagnostic performance was independently acquired by two reviewers. Meta-analysis was performed using a bivariate mixed-effects regression model. RESULTS: Fourteen studies were included with 12 studies evaluating liver stiffness and eight studies evaluating spleen stiffness. The pooled and weighted sensitivity, specificity, and area under the curve (AUC) values for liver stiffness on MRE were 83% [95% confidence interval (CI) 72-90%], 80% (95% CI 70-88%), and 88% (95% CI 85-91%), respectively. The pooled and weighted sensitivity, specificity, and AUC values for spleen stiffness on MRE were 79% (95% CI 61-90%), 90% (95% CI 80-95%), and 92% (95% CI 89-94%), respectively. The liver and spleen stiffness sensitivity and specificity values were comparable when evaluating for esophageal varices only at of 80% (95% CI 66-89%) and 76% (95% CI 62-86%) for liver stiffness, and 75% (95% CI 52-90%) and 89% (95% CI 70-96%) for spleen stiffness. DISCUSSION: Liver and spleen stiffness on MRE can serve as a supplemental noninvasive assessment tools for detecting clinically significant portal hypertension. Spleen stiffness may be more specific and accurate than liver stiffness for detecting portal hypertension.


Assuntos
Técnicas de Imagem por Elasticidade , Varizes Esofágicas e Gástricas , Hipertensão Portal , Varizes Esofágicas e Gástricas/diagnóstico por imagem , Varizes Esofágicas e Gástricas/etiologia , Humanos , Hipertensão Portal/diagnóstico por imagem , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/patologia , Baço/diagnóstico por imagem , Baço/patologia
20.
Skeletal Radiol ; 50(5): 871-879, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33090251

RESUMO

PURPOSE: This systematic review and meta-analysis evaluated the diagnostic accuracy of dual-energy CT (DECT) for detecting bone marrow edema (BME) in adult patients with acute knee injuries. METHODS: A systematic review of MEDLINE, EMBASE, Scopus, the Cochrane Library, and gray literature was performed from inception to January 31, 2020, using PRISMA-DTA guidelines. The review included studies assessing the diagnostic accuracy of DECT for detecting BME in at least 10 adult patients with acute knee injuries and with an MRI reference standard. Study details were independently extracted by two reviewers. Meta-analysis was performed using a bivariate mixed-effects regression model with subgroup analysis performed to evaluate for sources of variability. Risk of bias (ROB) was evaluated using the QUADAS-2 tool. RESULTS: Eight studies evaluating 267 patients between the ages of 25-54 with acute knee injuries undergoing DECT and MRI were included in analysis. Summary sensitivity, specificity, and AUROC values for BME were 84% (95% confidence interval (CI) 74-91%), 96% (95% CI 93-98%), and 0.97 (95% CI 0.95-0.98), respectively. Bone-based characterization was found to have lower specificity than region-based characterization (83% (57-95%) versus 97 (96-98%), p < 0.05), but no difference in sensitivity. No other statistical differences were identified amongst study subgroups to account for presumed variability amongst studies. Most studies were rated low risk for bias and applicability concerns. CONCLUSION: DECT is specific and accurate for detecting BME in adult patients with acute knee injuries and can be used as an alternative to MRI, particularly when MRI is contraindicated or unavailable.


Assuntos
Medula Óssea , Traumatismos do Joelho , Adulto , Medula Óssea/diagnóstico por imagem , Edema/diagnóstico por imagem , Humanos , Traumatismos do Joelho/diagnóstico por imagem , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...